广西某尾矿库岩溶水文地质条件及连通试验探究

    Investigation of karst hydrogeological conditions and connectivity tests at a tailings pond in Guangxi

    • 摘要: 研究地下岩溶是否存在相互之间的水力联系,地下水连通试验是一种行之有效的方法。以广西某尾矿库为例,通过掌握研究区域内水文地质条件,查明区内含水层特征及地下水的补、径、排方式,通过珊瑚河流量监测,查明了珊瑚河地表水主要来源于地下水补给,地下水补给占本段河道补给的63.3%左右,珊瑚河为杉木冲次级水文地质单元排泄边界。通过进一步野外的连通试验表明,各钻孔与新民村岩溶泉、珊瑚河、水塘等之间无岩溶管道联系,论证了原尾矿库勘察报告中下部岩溶充填率达97.4%的结论的正确性。目测比色分析法最低可见为0.097 6 mg/L及采用荧光灯照射法检出限为0.024 4 mg/L,与采用分光光度法相差19.52倍和4.88倍,相差倍数不大,采用目测及荧光灯照射法、比色分析法基本上可以满足野外简易监测使用,且简单易于掌握,特别适合于委托当地临时监测员使用。

       

      Abstract: Investigating whether there is a hydraulic connection between underground karst systems can be effectively achieved through groundwater connectivity tests. Taking a tailings pond in Guangxi as an example, by understanding the hydrogeological conditions of the study area, the characteristics of the aquifers, and the recharge, flow, and discharge patterns of groundwater are identified. Through flow monitoring of the Shanhu River, it is determined that the surface water of the Shanhu River primarily originates from groundwater recharge, accounting for approximately 63.3% of the river’s recharge in this section. The Shanhu River serves as the discharge boundary for the secondary hydrogeological unit of Shanmuchong. Further field connectivity tests revealed no karst conduit connections between the boreholes and the karst spring in Xinmin Village, the Shanhu River, or the ponds, validating the conclusion in the original tailings pond survey report that the lower karst filling rate is 97.4%. The visual detection limit of the colorimetric analysis method is 0.097 6 mg/L, while the detection limit using the fluorescent lamp irradiation method is 0.024 4 mg/L, which are 19.52 times and 4.88 times different from the spectrophotometric method, respectively. The difference is not significant, and the colorimetric analysis method using visual inspection and fluorescent lamp irradiation can basically meet the requirements for simple field monitoring. It is easy to use and particularly suitable for temporary local monitors entrusted with the task.

       

    /

    返回文章
    返回