VENTILATION AND DUST PREVENTION OF BELT-CONVEYOR DECLINE AT OPEN PIT MINE
-
Abstract
In view of serious dust polution in belt conveyor decline of open pit iron mine and by taking the Eeast Decline of Dagushan Iron Mine as a sample, this paper emphasizes the importance of mechanical ventilation;describes the effects of continualy supplying fresh air on the dilution and emission of dust laden air flow and on the decrease of relative humidity;analyses the possibility of putting it into practice;and demonstrates that how determine the air flow rate (air quantity) in belt conveyor decline and relation between it and air flow direction.At last, a reconstruction design of ventilation and dust prevention of the East Belt Conveyor Decline is presented.
-
-